Pump Control Unit PGS
The PGS pump control unit is used together with a transducer supplying a standard power signal of 0 or 4 to 20 mA (e.g. immersion transmitter ETG) as a convenient, intelligent and decentralized control system in all drinking water and waste water technology applications that require an exact determination of the level, pressure or the flow quantity, the exact setting of the limited values, simple operation and a high degree of operational safety.
The PGS pump control unit assigns a level with the unit “m water column” to the standard power signal 0/4 … 20 mA supplied by the transducer (in the case of pressure the unit “bar” and in the case of flow quantity the unit “l/s”).
Scaling e.g. for the level, is either via the maximum value from the transducer (ETG) at 20 mA or via the actual value (momentary value). The scaling is defined in steps of tenths or hundredths. The indicator value is calculated according to the input power and the scaling that is set. It is also possible to provide a scaled percentage indicator. The value of the analogue output changes in accordance with this scaling whereby 100% corresponds to 20 mA or 5/10 V at the output.
All the limited values can be determined with the measuring range. For all three limited value pairs the turn-on value can be above or below the turn-off value (fill or empty tanks). Cyclical alternating of two or three limit value contacts balances the load of the connected pumps to ensure uniform wear.
A high degree of operational safety is ensured by the measuring system being continuously supervised. Errors, cable parting or short-circuits, corresponding to the lower deviation from the programmed zero point or the permissible input power being exceeded, are indicated in clear text and also as a potential-free fault. The parameter setting for all functions does not require additional programming equipment and is carried out with 3 keys. For the sake of easy operation it is fully menu guided.
A separate constant voltage supply provides the transducer with the auxiliary power required.
Technical data
Degree of protection | Front: IP 54 |
Material | Kunststoff, ABS |
Memory
Parameters | EEPROM |
Data / measurement | SD-Card (Option) |
Total error
Measurement accuracy | < +/- 1 |
Display
Display | Grafische LCD, 128x64 Punkte hinterleuchtet |
Update measured value | alle 2 s |
Display area | 0 ... 999999 |
Unit | wählbar |
Percentage display | 0 ... 999,9 |
Dämpfung | In 15 Stufen wählbar |
Output
Contacts | 3 Schließer, 1 Wechsler, "Störung" |
Switching capacity | 250 V/50 Hz, 2A max 200 VA |
Number | 0/4... 20mA, Bürde max. 500 Ω |
D/A-transformer | 12 |
Input
Number | 4... 20 mA (aktiv) oder 0/4... 20 mA (passiv) |
Input resistance | |
A/D-transformer | |
3 dB Grenzfrequenz | 21 |
Power supply
Operating voltage | 230 V / 50Hz oder 24 V/DC, je nach Gerätetyp |
Power consumption | ca. 8 |
Integrated help energy source | 24 V DC max 50 mA |
Handling is very simple and reliable.
Accessories:
Related products: