Submersible transmitter ETG 30 (ATEX)
The submersible transmitter is utilised to provide continuous level measurements in waste and industrial water plant.
A ceramic pressure sensor and the electronics convert the hydrostatic pressure into a proportional electrical signal.
The bearer cable contains a pressure compensation tube to compensate for atmospheric pressure fluctuations. The submersible transmitter is supplied as 2- wire version providing output signal 4- 20 mA as well as with measurement ranges up to 100.00 mWS.
Technical data
Operation voltage | 11,5...30 |
min. | 1 |
max. | 0...100,0 mWS and all intermediate values |
Current
2-wire-execution | 4...20 |
Max. load | (Ub[V]-10,5V)/20 |
Measurement error
Linearity | <0,5 |
Long term stability | 0,5 |
Temperature drift | <0,01 |